Tablet Disintegration Apparatus (Manual) About
The image shows a Tablet Disintegration Test Apparatus (Double Unit), a laboratory instrument used in pharmaceutical quality-control testing to determine the disintegration time of tablets and capsules.
Main parts:
- Two disintegration baskets: Allow two test samples to be tested simultaneously.
- Beaker/test vessels: Contain the specified disintegration medium, usually water or another suitable liquid.
- Reciprocating mechanism: Moves the baskets vertically at a controlled rate to simulate the conditions required by the pharmacopoeial test.
- Temperature control/heating arrangement: Maintains the test medium at the specified temperature, commonly around 37 2C.
- Control panel: Contains separate controls for the two units, including ON/OFF switches and timers/speed controls.
- Motor and drive assembly: Provides the up-and-down movement of the baskets.
- Stainless-steel construction: Provides durability and resistance to corrosion.
Dual Basket Design for Efficient TestingThis apparatus is equipped with two stainless steel (SS 316) baskets, enabling the simultaneous disintegration testing of multiple tablet samples. The double-basket setup enhances productivity in research and quality control environments, streamlining workflow without compromising accuracy or reproducibility.
Precision Temperature Control and SafetyUtilizing a capillary-type thermostat, the apparatus allows precise manual temperature adjustments up to 50C, maintaining optimal water bath conditions. Borosilicate glass beakers and thermal insulation ensure safety during operation, while the immersion heater offers reliable, corrosion-resistant heating.
Adaptable for Laboratory RequirementsCompliant with international standards (IP/USP/BP), this versatile instrument is designed for broad adaptation in pharmaceutical laboratories. Its chemical-resistant construction and user-friendly front panel manual controls make it suitable for routine testing, research, and regulatory quality assessments.
FAQ's of Tablet Disintegration Apparatus (Manual):
Q: How is the tablet disintegration process conducted using this manual apparatus?
A: To conduct tablet disintegration testing, tablets are placed in the stainless steel baskets submerged in borosilicate glass beakers filled with appropriate testing media. The manual controls allow you to regulate the stroke rate and temperature, ensuring compliance with standard protocols for disintegration time measurement.
Q: What is the benefit of having double baskets and dual beakers in this disintegration apparatus?
A: The dual basket and beaker setup allows concurrent testing of two separate tablet batches, increasing laboratory efficiency and productivity by enabling side-by-side comparison or batch analysis, saving valuable time and resources.
Q: When should the manual timer be used during testing?
A: The manual timer is engaged at the beginning of the disintegration test and stopped once the tablets have fully disintegrated, allowing you to record disintegration times accurately as per standard operating procedures.
Q: Where is this apparatus typically used?
A: This manual tablet disintegration apparatus is commonly used in pharmaceutical laboratories, research centers, and quality control departments for testing the disintegration time of tablets under controlled conditions.
Q: What types of materials are used in the construction of the apparatus?
A: The apparatus uses stainless steel (SS 316) for baskets, borosilicate glass for beakers, and mild steel finished with chemical resistant powder coating for the main body, ensuring durability and longevity in demanding laboratory environments.
Q: How does the instrument maintain a safe and stable operating temperature?
A: A capillary thermostat provides manual temperature control up to 50C, while thermal insulation and an immersion-type heater ensure steady and safe heating conditions throughout the test, protecting users from accidental thermal exposure.